Answer a Question with a Question: Slurry Testing Frequency

Answer a Question with a Question: Slurry Testing Frequency

I am frequently asked how often should I test my slurry?  I know you shouldn’t answer a question with a question, but what about a series of questions?

question-face-200x117
✓ How often do you have to make adjustments to your slurry?

✓ Are the adjustments with water, binder or a mixture of both?

✓ Do the components of the adjustment change every time?

✓ Do you have to add so many liquids that flour needs to be added to thicken up the slurry?

✓ Are these adjustments as a result of periodic viscosity checks or from the slurry testing?

The goal of your testing frequency should be as little as possible while ensuring the key parameters are in range.  I have seen some customers test their slurries on a daily basis and some do no testing at all.

I firmly believe that if you control your inputs, slurry control will be much easier and a result, less testing is required.  That means that you must monitor the material being fed into the slurry tanks and make adjustments prior to adding them into the dip tanks.  If the make-up tanks are in range, it would stand to reason that the slurry dip tanks will also be in range.  But, what if the make-up tanks aren’t maintained in range?

If you have questions about how to ensure the make-up tanks are in control, read Shark Teeth or an Iowa Cornfield?

If you start to understand why the adjustments are being made and take steps to correct those parts of the process which are causing the variability, then you will be on your way to having a more robust process which will allow the operators to spend less time testing the slurries and more time on production.

If you want to talk about where your process variability might be coming from, send me a quick email at Julie@keyprocessinnovations.com  and we can discuss your situation in greater detail.

 

Hitting the pH Target

Hitting the pH Target

Stability of colloidal silica is important for the health and performance of an investment casting slurry.  pH is one indicator as to the stability.  Conductivity is another important indicator and information on that topic can be found here.

Accurate measurement of pH is critical.  I have received numerous phone calls from customers stating that the pH of the slurry is 11.0 or even higher.  If the pH of a silica-based sample is above about 10.5, the silica particles can begin to dissolve.  Since the slurry additives typically lower the pH, a reading of 11.0 could indicate issues with your meter.

1071008_14843726If you are unsure if the pH is giving accurate results, check the pH of the incoming colloidal silica and compare the reading to the supplier’s certification.

The trending of the pH over time is as important, if not more important, than an absolute value.  For example, a pH of 9.2 could be a reason for concern.  However, if the pH has been slowly drifting down to 9.2 and then settling there, the slurry stability may be fine.  Checking conductivity is another way to confirm the health of the slurry.

Care of a pH meter will vary by manufacturer.  Take some time to review the manual and ensure that the proper calibration and maintenance procedures are followed.

If you are still unsure of your readings, feel free to contact me for more information at Julie@keyprocessinnovations.com.

Clean Calibration: Maximizing Slurry Test Results

Clean Calibration: Maximizing Slurry Test Results

One of the most common slurry tests performed for investment casting slurries is SiO2 percentage.  Insufficient concentration of SiO2 in the slurry creates a weak shell.  However, having too high a concentration can also cause a weak shell while potentially gelling the slurry.

The two common methods for measuring binder solids are volumetric and through the use of a densitometer.  For this discussion, we will focus on the volumetric method.

Ensure that the sample has been spun long enough to remove the refractory particles from the supernate (liquid on the top of the solids).  If this isn’t done, the results will be inaccurate, regardless of the test method utilized.

Of the two methods, the volumetric procedure can lead to the most variability.  This variability can come from the following:
1. Uncalibrated flasks
2. Dirty flasks
3. Fill line identification

Water to calibrate flaskMost foundries make the mistake of assuming that a 10 ml volumetric flask filled with water will weigh10 grams.  Making this assumption could lead to inaccurate results.  However, if you compound this error with a dirty flask and the results will be even further off.  I have seen the percentage of silica be off by up to 3 percentage points by not calibrating a dirty flask.

The other challenge that operators sometimes face is knowing how to locate the meniscus.  By going through the calibration process, this can help operators understand how a slight difference in the fill line can impact the results.

The ICI has outlined a procedure on how to calibrate your flasks every time the test is performed.  Or, if you have questions, feel free to contact me for more information at Julie@keyprocessinnovations.com.

Data Collection and Slurry Control

Data Collection and Slurry Control

I had a wise customer comment to me once that he didn’t mind collecting data as long as the operators/engineers were going use it for slurry control.  I completely agree with that statement but would add: make sure the data you are gathering is meaningful.
Movie on 5-7-12 at 12.09 PMSo, what does meaningful data look like?  In my mind, it would be data that you could rely on to troubleshoot issues within your process.  One of my favorite examples was a customer who was measuring the pH of a slurry but his pH probe would never stabilize prior to turning off.  Instead of resolving the issue, he would record the last reading he saw before the meter shut off.

Then, his slurry gelled – all 250 gallons.  In the tank.

So, I received the panicked call that his slurry had gone bad and he didn’t know why.

When I asked about the pH of the slurry and if it had been trending down, he said he didn’t know.  I asked if he had been testing for bacteria and he said yes, but was out of biocide.  I asked if he had been checking conductivity levels and he said no.

Though he did a great job recording his data and graphing it for all to see, his data wasn’t accurate and he couldn’t use it for its intended purpose.  It was an expensive lesson for the engineer and the company.

Collecting data for the sake of compiling a graph does not help you achieve the ultimate business goal of making castings.  And, if you don’t have any confidence in the testing method, the technician or the result, than you might consider utilizing your resources in another capacity.

In the next few weeks, we will discuss ways to ensure you have robust slurry testing procedures.

A Balancing Act: Managing Slurry Conductivity

A Balancing Act: Managing Slurry Conductivity

Last week, we discussed conductivity and how high levels can contribute to reduced slurry health.  Now, we will discuss potential causes and what can be done about it.

Some common causes of high conductivity are:
♣ Increase in the number and strength of ions
♣ Bacteria
♣ Additions to the slurry

Most colloidal silica used in this industry is sodium stabilized.  Sodium has a lower ionic strength than Iron, Calcium or Aluminum.  As the concentration of ions increases in the slurry, especially higher strength ions, conductivity will increase.

_dsc7539_1One source of these higher strength ions is refractory flours.  Some refractories have a high level of impurities that will leach out into the slurry.  When this happens, the conductivity will rise and the pH will fall.  The lower the slurry turnover rate, the greater the risk for slurry instability.

One way to remove these impurities is through the use of a rare earth magnet.  There are a number of ways to install these magnets but, whichever method you choose, make sure they are easily accessible for cleaning.  If you don’t clean the magnet on a regular basis, you will not reap the benefits.  Start by checking it daily.  As the build-up on the magnet decreases, the cleaning frequency can be reduced.

The presence of microbiological activity can also cause slurry conductivity to rise and pH to fall.  If you experience this phenomenon, check for bacteria.  If detected, treat with biocide, ammonium hydroxide or bleach.

However, using bleach to treat bacteria can have some other consequences including increased slurry conductivity, oxidation of polymers and reduction in shell hot strength.  Do some investigation to identify the root cause of the bacteria.  And then establish a regimen for preventing growth of bacteria in the slurries.

The unfortunate truth is there is no direct way to adjust conductivity, so it is important to take the appropriate steps to prevent slurry conductivity from climbing in the first place.  But by following the tips above, you have the necessary tools to maintain conductivity levels in the optimal range.